Zone 1 – the area directly above zone 0, limited vertically to 2.25m above the bottom of the bath or shower, also 1.2m horizontally from the centre of a shower outlet to the height of the outlet, or 2.25m whichever is the higher visitor adaptors (e.g. http://www.roamingfox.co.uk/UK-Visitor-Travel-Adapter-pr-16228.html ). Theese have a higher current rating than shaver adaptors and can be used with some earthed plug types. However THEY WILL NOT PROVIDE AN EARTH TO GERMAN/DUTCH/FRENCH plugs. You have to be particularlly carefull with the german/dutch schuko plugs because they use side clips not pins for earthing. This means it is easy to end up with a situation where an appliance that needs earthing for safe operation has it's live and neutral pins connected but not it's earth pins. You can only use shavers & toothbrushes with that adaptor, nothing larger & nothing that requires an earth connection. As previously mentioned, if you are sing a lighting circuit make sure it’s RCD protected. If it isn’t then you can’t use it.

Masterplug 3-Pin Fused Shaver Adaptor - Screwfix

Ideally look for a model with double wound isolating transformer, integral overload protection and shutters on the plug inlets to prevent any accidental splashing. shaver adaptors: (e.g. http://www.maplin.co.uk/Module.aspx?ModuleNo=1186&DOY=31m3#features) theese are designed for shavers and can also be used for other very small <1A appliances that do not require earthing and come with a two pin europlug (a relatively thin plug with two thin flexible pins). They are NOT suitable for either applicances that require higher currents or those that require earthing It seems indeed to be the right conclusion to cut and replace the Euro (schuko) earth plugs to British ones alltogether. I am moving from the Netherlands to Ireland and I bought many European to UK travel adaptors to fit my (European plug) appliances which I'm intending to take with me. They are shaver adaptors with a 1 Amp fuse. Now, after doing some more research, I came to realize that this plug as it is, will do for shavers and electric toothbrushes but not for other appliances. For those "other" appliances that I want to use in Ireland can I change that existing 1 Amp fuse with a 3 Amp fuse or a 5 Amp fuse or a 13 Amp fuse? I am aware and already realize that I cannot use these adaptors for my washing machine and I also do not intend to take my refrigerator with me but what about the rest? Zone 0 – the interior of the bath or shower which can hold water. No appliances should be installed here period!Suitable for accepting the plugs fitted to electric shavers and standard 2-pin continental mains plugs" In the UK there are very strict rules on who can and cannot do certain electrical jobs. This is mainly due to the fact that, as we all know, electricity is extremely dangerous and when working on or around it, it is essential that you know what you are doing. Plugwash's final suggestion is the one to go for - just change the plugs on your appliances and have done with it. If no supplies are this conveniently placed then it may be that you have to take up some floorboards in an above room and run your supply from here. Once all the wires have been connected, the face plate is then screwed on to the pattress box, fixing it in place.

Shaver Sockets | Shaver Points | Screwfix Shaver Sockets | Shaver Points | Screwfix

Below is another example of the same plug I bought (I bought the same type at ASDA) and it has a plastic grounding with a 1 Amp fuse. Once a suitable supply has been found the next task is to isolate the supply to the circuit you are using! If in any doubt, the power to the entire house is turned off. The cable is then normally capped (covered with a protective UPVC capping) or run through some UPVC trunking/pipe to protect it and hold it in place. In this example here we are using an existing lighting circuit so a 1mm twin and earth cable is run out from the top of the ceiling rose, down through the ceiling and down a chase that was cut into the wall. Once in place the cable was then tested to ensure there were no breaks etc. This is a necessary step as once the cable is filled over it’s a nightmare to have to dig it all out if it’s damaged.There are adaptor plugs available to safely convert these to the UK style plug without having to take the existing plug off. A Rating Ideal for all Applications - 3A for up to 720W, 5A between 720W and 2100W, 10A between 2100W and 2400W, 13A between 2400W and 3120W If either of the above are ignored, if any issues occur and you cannot produce a certificate for the works then there is a good chance that your home insurance will be invalid, so it certainly isn’t worth the risk.

Fitting an Electrical Shaver Socket | DIY Doctor

The cable was then secured in place using UPVC capping to not only hold it but also protect it from any damage that might from any potential future work. Zone 2 – the area beyond zones 0 and 1, 0.6m horizontally and up to 2.25m vertically. Zone 2 also includes any recessed window with a sill next to the bath and also around the wash basin Once this is done, a minor works certificate is then issued to prove the installation has been carried out correctly. There are many types of adaptors on the market and knowing what is suitable for what purpose is important to get a safe and reliable result. No, I meant my own european shaver has a plug similar to the standard 2 pin thin plug which is in use with some non-earth products. By the way, do you have any comment on my message to Plugwash? Thanks!Hard to see how that's true, as shaver plugs and standard 2-pin continental mains plugs have different spacing. Yes you can force them in but I'd not agree that makes it "suitable". When securing wires ensure that the retaining screw that holds the wire in place is tightened fully and that it has plenty of bare wire to clamp down on to. In both cases, the cables are run down through the ceiling and down a chase cut into the wall to run to both locations

UK 2 to 3 Pin Adaptor Plug For Shavers And Toothbrushes

However if you are installing in an upstairs then you may be able to locate a suitable supply in the loft. This is often the easiest route as everything should be much more accessible. Wall chased out and cable placed in chase and protective UPVC pipe Step 3 – Install Fused Connection Unit (FCU) And that means that you should not replace the fuse or use it for anything which draws more than 1A.