WIND GENERATOR CIRCUITS: At most locations, a wind generator produces its full rated current only during occasional windstorms or gusts. If wire sized for low loss is large and very expensive, you may consider sizing for a voltage drop as high as 10% at the rated current. That loss will only occur occasionally, when energy is most abundant. Consult the wind system’s instruction manual. You might find it useful to read our Electrical Circuit Basics article for using the equation I = P/V where the following example is given: ALUMINUM WIRE may be more economical than copper for some main lines. Power companies use it because it is cheaper than copper and lighter in weight, even though a larger size must be used. It is safe when installed to code with AL-rated terminals. You may wish to consider it for long, expensive runs of #2 or larger. The cost difference fluctuates with the metals market. It is stiff and hard to bend, and not rated for submersible pumps. A general rule is to size the wire for approximately 2-3% drop at typical load. When that turns out to be very expensive, consider some of the following advice. Different electrical circuits have different tolerances for voltage drop.

AC INDUCTION MOTORS are commonly found in large power tools, appliances and well pumps. They exhibit very high surge demands when starting. Significant voltage drop in these circuits may cause failure to start and possible motor damage. Follow the National Electrical Code. In the case of a well pump, follow the manufacturer’s instructions. In North America the AWG standard is most commonly used for stranded cable and expresses the Gauge together with the number of strands and their Gauge. For example, a cable specified as 16 AWG 7/24 has a size of 16AWG and is made up of 7 individual strands, each of 24 AWG.This is the resistance of the conductor expressed in Ohms per metre ( W/m) and is important when determining voltage drop (see below) Each component or appliance connected to a circuit will have a current draw associated with its operation and it is important that the cable supplying power to these is capable of carrying the normally expected current, plus a margin of safety. If it is not capable then it is likely to result in the cable becoming hot and potentially catching fire. Although fuses are used in the circuit to protect the cable, the cable itself should be of an adequate rating to prevent this over-heating occurring under normal circumstances. This chart works for any voltage or voltage drop, American (AWG) or metric (mm2) sizing. It applies to typical DC circuits and to some simple AC circuits (single-phase AC with resistive loads, not motor loads, power factor = 1.0, line reactance negligible).

This shows that 1.5mm² cable (at a current rating of 21A) will be suitable for the cable run length as the drop is well under 3%Expressed in Amperes (Amps or A) and is the maximum continuous or 'working' current that the cable can safely carry. The table below provides a cross-reference between these two standards, showing the closest metric equivalents to each Gauge for cable sizes commonly used in low voltage automotive and marine applications. AWG

LIGHTING CIRCUITS, INCANDESCENT AND QUARTZ HALOGEN (QH): Don’t cheat on these! A 5% voltage drop causes an approximate 10% loss in light output. This is because the bulb not only receives less power, but the cooler filament drops from white-hot towards red-hot, emitting much less visible light.

Enter values, hit ENTER/RETURN key to calculate

The cable size results for International standard cable are calculated from IEC 60364-5-52: Low Voltage Electrical Installations, selection and erection of electrical equipment – Wiring systems and are based on 230V and 415V voltage drop. In both BS and IEC calculations, the KW calculation is based on a power factor of 0.8. PV BATTERY CHARGING CIRCUITS are critical because voltage drop can cause a disproportionate loss of charge current. To charge a battery, a generating device must apply a higher voltage than already exists within the battery. That’s why most PV modules are made for 16-18V peak power point. A voltage drop greater than 5% will reduce this necessary voltage difference, and can reduce charge current to the battery by a much greater percentage. Our general recommendation here is to size for a 2-3% voltage drop. If you think that the PV array may be expanded in the future, size the wire for future expansion. Your customer will appreciate that when it comes time to add to the array. This problem is overcome by manufacturing the core from many small diameter strands of copper wire to make up the desired cross-sectional area, rather than using a single wire. This type of cable is (unsurprisingly) known as 'stranded' cable and provides much more flexibility, which means improved resistance to work hardening making it better suited to use in vehicles. The difference in cross sections is shown in the diagram below: In Europe, metric sizes are used for stranded cableand are expressed as the total cross sectional area of the conductors together with the number of strands and their diameter. For example, a cable specified as 2.0mm² 28/0.30 indicates that it has a total conductor cross sectional area of 2.0mm² and is made up of 28 individual strands, each of 0.3mm diameter.

DC MOTORS may be used in renewable energy systems, especially for water pumps. They operate at 10-50% higher efficiencies than AC motors, and eliminate the costs and losses associated with inverters. DC motors do NOT have excessive power surge demands when starting, unlike AC induction motors. Voltage drop during the starting surge simply results in a “soft start”.

Universal Wire Sizing Chart

Anyway, enough maths - to make it easy we've developed this handy calculator which will show you the approximate voltage drop based on cable size, supply voltage, current draw and cable length. Low voltage automotive and marine cable is available in different materials/constructions and the following table gives a brief overview: Material Eland Cables' Cable Calculator can help you determine the most appropriate cable size for your installation against British and IEC standards. Complete the sections below to calculate your results. There is a general rule of thumb that says if you're unsure whether the cable is large enough for the job, go up a size. This is a bit crude and not very scientific but it's not a bad rule to apply as increasing cable size can't do any harm. NOTES: AWG = American Wire Gauge. Ampacity is based on the National Electrical Code (USA) for 30°C (85°F) ambient air temperature, for no more than three insulated conductors in raceway in free air of cable types AC, NM, NMC and SE; and conductor insulation types TA, TBS, SA, AVB, SIS, RHH, THHN and XHHW. For other conditions, refer to National Electric Code or an engineering handbook.