Before delving into the detail of this change, as ever it pays to start at the beginning – namely the Fundamental Principles of Part 1.

So I2t is actually a function of the prospective fault current, and is either depicted graphically, or listed as spot values . For mcbs made to the IEC standards since 1999 or so this is a spec parameter, and guaranteed by design. for earlier devices it isn't For this reason, regulation 536.4.203 states that ‘The relevant part of the BS EN 61439 series shall be applied to the integration of mechanical and electrical devices and components, e.g., circuit-breakers, control devices, busbars into an empty enclosure or existing low voltage assembly.’ Which leaves you with the lighting circuits - how far down the cable do you need to go, if the 3kA value is present at the DB, using 1.5mm2 conductors before you are safe again - not far I suspect. Additionally, any commercial, industrial, or public building that is supplied by overhead lines requires surge protection – so the majority of buildings will require surge protection. Residential properties will depend on use and occupancy levels.Every item of equipment shall comply with the appropriate British or Harmonized Standard.’ For distribution boards, this is the BS EN 61439 series. Part 3 is a specific part of the BS EN 61439 suite and it includes requirements for Distribution Boards intended for use by ‘ordinary persons’. OK - I was assuming 90C/250C (ie XLPE insulation and K of circa 150) so you should be OK for 2.0mm2 and upwards - which should exclude a whole load of circuits from your assessment.

Step 2 remember that for AC circuits the voltage is a constantly changing value, and when we give a single number, it is a form of average voltage, called the RMS voltage. The RMS voltage of an AC waveform corresponds to the DC voltage which would deliver the same power to a resistive load. If you take AC at 480V RMS and apply it to a 480 ohm resistor, the average power delivered to that resistor would be 480W. If you take DC at 480V and apply it to a 480 ohm resistor, the power delivered to that resistor would be 480W. The values of earth loop impedance shown in these tables must compensate for conductor temperature rise, if the measurement of loop impedance is taken at ambient temperature. A useful rule of thumb is to allow for a temperature rise from 20 degrees to 70 degrees by multiplying the listed value by 0.8. The measured value can then be compared to the compensated value. Of note here is that a protective device may conform to the appropriate product standard (e.g. BS EN 60898) and be UKCA marked. If the devices are from different manufacturers, they are likely to be designed differently and will perform differently – though both may comply with the appropriate safety requirements of BS EN 60898.

New Requirements

At time zero, phase A is zero, but phase W is negative, say by a couple of volts. Then at time 1/240 phase A is at its positive peak, but phase W is slightly below. A teensy bit later, phase A is on its way down, and phase W hits its peak. And so on through the cycle. Both phases have the same amplitude, but hit their peaks at different times. There is usually a slightly different voltage between the two, but since sometimes A is more positive and sometimes W is more positive, the two graphs _must_ cross. is a nice number for rules of thumb , 1.6mm is nearly 1/16 of an inch and almost exactly the diameter of 16 standard wire gauge and 16 Birmingham sheet metal gauge, though not american wire, but AWG 14 is ~ 1.6mm dia. ) Step 1 is to remember that voltage is _always_ measured between two points. So when you say that a particular circuit is 277/480V wye, you provide the following information: Measured phase to phase the voltage is 480V. Measured phase to neutral the voltage is 277V. The source is wye connected, eg. a transformer bank with 277V secondaries. All SPDs work by diverting surge currents to earth to reduce the over-voltage to a level that will not damage the components of the system or equipment connected to it. There are three types of surge protection devices: Type 1 K~ 145 for rubbers and 115 for PVC insulation , with certain assumptions about starting temperature.

Asda Great Deal

Free UK shipping. 15 day free returns.
Community Updates
*So you can easily identify outgoing links on our site, we've marked them with an "*" symbol. Links on our site are monetised, but this never affects which deals get posted. Find more info in our FAQs and About Us page.
New Comment